high speed and accuracy high torque low drift compact and tight dust- and interference-proof easy to install effective heat-sinking system
Marking Marking-on-the-fly Laser therapy Science and research
Model
S-9210M
Aperture size( mm)
10
12
Max. scan angle
±12.5°
Max. laser power(W)
Nd:YAG@1064 nm
120
150
CO2
70
100
Small step response time(1)(ms)
0.22
Tracking error(ms)
0.12
Marking speed(2)(m/s)
4
3
Positioning speed(2)(m/s)
18
Writing speed(3)(cps)
good quality
800
680
high quality
690
520
Zero drift (μRad./℃)
<15
Scale drift ( ppm/℃)
<50
Long-term drift over 8 hours ( mrad.)
<0.5
Linearity(4)
≥99.90%
Repeatability(μRad.)
<8
Max. RMS current (A/axis)
2.5
Peak current (A)
15
Input signals
DC±5V, ±10V(analog signal)
Input power
±24 VDC,Max. 3.5A/axis
Operating temperature
25℃±10℃
Weight(kg)
0.8
Application
High speed mark
Mark-on-the-fly
Trimming
Research&science
- All angles are in mechanical degrees.
- All above specifications are applicable after 60 sec warm-up.
(1)Settling to 1% of full scale with Min. Y mirror which the scanner can carry.
(2)With F=160mm lens.
(3)With F=160mm lens,mark 1mm height SHX font characters(including letters and digits)
(4)Within ±20° optical angle.
Request Datasheet forS-9210 2D Scanning System systems with mechanical drawings
请填写以下信息,以便我们为您提供更好的服务。